    High-temperature insulated wire isn’t an one-size-fits-all product. Based on the application, different factors go into choosing the proper type of wire to obtain the task finished right. In this posting, we’ll keep an eye on at what these factors are and how they’re able to assist in choosing the ultimate high-temperature insulated wire for ones specific situation.

    Factor #1: Definition of Electrical Requirements – Operating voltage, conductor temperature rating and current-carrying capacity (aka ampacity) must all be met when scouting for high-temperature insulated wire. Such wiring is labeled which has a temperature rating, that is determined by a mix of ambient heat and current-generated heat. Ambient heat stems from the applying being performed whereas current-generated heat is calculated by matching conductor material and diameter to service amperage. It is very important observe that due to difficulty in pinning down exact current-carrying capacity, product designers often specify higher capacity conductors than theoretical calculations would indicate.

    Factor #2: Environmental Conditions – What are you doing inside the wire is not only consideration in terms of choosing the right high-temperature insulated wire. External environmental factors can also be important. Like they are able to use a damaging impact on the wire’s insulation as well as interior circuitry. Ambient heat, moisture, abrasion, thermal stability, chemical attach, mechanical abuse, low temperature, flame resistance, simplicity of stripping terminating and routing are all environmental problems that should be compensated for when selecting high-temperature insulated wire. Some factors are discussed in depth further on on this page.

    Factor #3: Conductor Material Type – The wire’s conductor material determine the utmost temperature it could withstand. Situations that want the wire to pass through the best of temperatures, like high-rise alarms in the eventuality of a fire, may well be more reliably served with nickel-coated copper and nickel conductors, each of which can endure temperatures as much as 550 degrees Celsius. Copper, nickel-plated and iron conductors on the other hand can take up under only a maximum array of 200 to 250 degrees Celsius.

    Factor #4: Current-Carrying Capacity or Ampacity – A lot of the environmental conditions talked about above also provide an effect on high-temperature insulated wire’s power to carry current. Consequently, they should be weighed into the equation. Ampacity is measured as the current a conductor can transport before the combined temperature of both conductor and insulation rises above a permitted limit.

    Conductor size and material, amperage, ambient temperature and insulation type will all be the cause will be the wire’s ampacity. The conductor’s diameter and mass are the most influential size considerations. The lesser these are, the lower the high-temperature insulated wire’s ampacity. As previously stated in the Factor #3 section, a conductor’s material carries a strong relating how much temperature the wire can withstand knowning that temperature range varies widely. Likewise, different materials produce wide fluctuations inside the current-carrying capacity from the wire also.

    Finally, the type of insulation used in the wire will determine simply how much heat it dissipates and, consequently, the ampacity. The dissipation problem becomes even more complicated when wire is enclosed in the tightly confined space, so fire alarms in high-rise ductwork, as an example, pose additional challenges when evaluating high-temperature insulated wire options.